FA cables for moving parts

 

CL-K series

Overview

This cable corresponds to moving parts.
Available in medium and base configurations.

Features

  • Supports moving parts.
    Can be used in medium and base configurations

Name

PoCL type: CL -K - (2) -P - (3) Non-PoCL type: CL -K - (2) - (3)

(2) : Connector combination symbol(See page 54・55) (3) : Cable length symbol(See page 55)*1

  • *1: In the case of PoCL, the cable length must be 10 m or less due to power source restrictions.

Specifications

  Type PoCL type Non-PoCL type
Cable UL UL 758 Style 20276
Rated temp./volt 80˚C / 30 V
Jacket material PVC
Color BLack
Outer diameter Standard 8.0 mm
Flame retardant VW-1
Complete product PoCL Supported Not Supported
Connector type MDR or SDR (26-pin)
Connector color See Lineup table (page 55)

Performance

Transmission distance 10 m (at 66 MHz)
Skew [ps/m] 50 or less
Movement performance Sliding bending: 1 million times or more
Bend radius R = 100 mm
Bend speed: 18 times per minute
Sliding distance: 1000 mm *2
  • *2: Under Oki test conditions and methods. These values are for reference only and are not guaranteed values.

Usage environment

Application location Fixed or moving part
Operation temperature range -20 to 75˚C
Minimum bend radius(Recommended value)*3 Fixed: 35 mm or more
Mobile: 100 mm or more
  • *3: The minimum bend radius is the recommended value for stable use.
Inquiries regarding materials, consultations, and technology
Inquiry from Web: Inquiry form

Contact

Contact