FA cables for moving parts

 

CL-S series(UL758 Style 20276)

Overview

This is the thin type of standard product for fixed parts. It supports the medium configuration and the base configuration.

Features

  • A small-diameter cable.
    Can be used in medium and base configurations

Name

PoCL type: CL -S - (2) -P - (3)
Non-PoCL type: CL -S - (2) - (3)

(2) : Connector combination symbol(See page 54・55) (3) : Cable length symbol(See page 55)*1

  • *1: In the case of PoCL, the cable length must be 10 m or less due to power source restrictions.

Specifications

  Type PoCL type Non-PoCL type
Cable UL UL 758 Style 20276
Rated temp./volt 80˚C / 30 V
Jacket material PVC
Color Beige
Outer diameter Standard 7.5 mm
Flame retardant VW-1
Complete product PoCL Supported Not Supported
Connector type MDR or SDR (26-pin)
Connector color See Lineup table (page 55)

Performance

Transmission distance 10 m (at 66 MHz)
Skew [ps/m] 50 or less

Usage environment

Application location Fixed part
Operation temperature range -20 to 75˚C
Minimum bend radius(Recommended value)*2 30 mm or more
  • *2: The minimum bend radius is the recommended value for stable use.
Inquiries regarding materials, consultations, and technology
Inquiry from Web: Inquiry form

Contact

Contact