FA cables for moving parts

 

CL-KS series(UL758 Style 20276)

Overview

This low-skew cable enables high-speed, long-distance transmission for moving parts. Available in medium and base configurations.

Features

  • A low-skew cable that enables high-speed and long-distance transmission.
    Supports moving parts. Can be used in medium and base configurations.

Name

For PoCL/non-PoCL use : CL -H - (2) -P - (3)

(2) : Connector combination symbol(See page 54・55) (3) : Cable length symbol(See page 55)*1

  • *1: In the case of PoCL, the cable length must be 10 m or less due to power source restrictions.

Specifications

  Type For both PoCL/non-PoCL use
Cable UL UL 758 Style 20276
Rated temp./volt 80˚C / 30 V
Jacket material PVC
Color BLack
Outer diameter Standard 9.0 mm
Flame retardant VW-1
Complete product PoCL Supported
Connector type MDR or SDR (26-pin)
Connector color See Lineup table (page 55)

Performance

Transmission distance(guideline) 7m (at 85 MHz)
Skew [ps/m] 25 or less
Movement performance Sliding bending: 3 million times or more*2
Bend radius R = 100 mm
Speed: 70 times per minute
Sliding distance: 300 mm

Usage environment

Application location Fixed or moving part
Operation temperature range -20 to 75˚C
Minimum bend radius(Recommended value)*3 Fixed: 40 mm or more
Mobile: 100 mm or more
  • *2: Under Oki test conditions and methods. These values are for reference only and are not guaranteed values.
  • *3: The minimum bend radius is the recommended value for stable use.
Inquiries regarding materials, consultations, and technology
Inquiry from Web: Inquiry form

Contact

Contact