This is a made-to-order service for composite cables that combine core wires with a special elastomer as the insulation. Compatible with various conductor sizes.
| Scope of service | Standard variation range | |
|---|---|---|
| Type | Pair x pair configuration/Pair x core configuration/Core x core configuration | Pair x pair configuration/Pair x core configuration/Core x core configuration |
| Conductor size (Cross-sectional area of conductor) |
30 to 10 AWG 12 sizes in total (0.05 to 5.5 mm²) |
28 to 19 AWG 5 sizes in total (0.1 to 0.75 mm²) |
| Number of cores / Number of pairs | Pair x pair configuration: Up to 20 - core (up to 10 - pair) Pair x core configuration: Up to 30 - core (Up to 10 - pair + up to 10 - core) Core x core configuration: Up to 10 - core |
Pair x pair configuration: Up to 20 - core (up to 10 - pair) Pair x core configuration: Up to 16 - core (Up to 10 - pair + up to 6 - core) |
| conductor | Tin-plated, soft copper, twisting cable |
|---|---|
| insulator | Special elastomer |
| Insulator identification | Insulator body color |
| Shielding | Tinned annealed copper wire braid(Option) |
| Jacket material | Heat-/oil-resistant PVC |
| jacket color | black matte |
| Applicable standards/ratings | UL 758 Style 2517 105°C、300V / UL 758 Style 2586 105°C、600V |
| Flame retardancy | VW-1 |
| Usage environment | Fixed and moving parts between equipment and within equipment indoors |
| Operation temperature range | -10 to 105°C |
| Cross-sectional area of conductor mm² | Conductor size AWG | Conductor resistance Ω /km(20°C) | Insulator resistance MΩ -km(20°C) | Withstand voltage V·1 minute interval |
|---|---|---|---|---|
| 0.05 | 30 | 340 or less | 100 or more | AC2000 |
| 0.1 | 28 | 205 or less | ||
| 0.15 | 26 | 130 or less | ||
| 0.2 | 25 | 102 or less | ||
| 0.25 | 24 | 80 or less | ||
| 0.3 | 23 | 68 or less | ||
| 0.5 | 21 | 45 or less | ||
| 0.75 | 19 | 26 or less | ||
| 1.25 | 17 | 16 or less | ||
| 2 | 15 | 9.3 or less | ||
| 3.5 | 12 | 5.7 or less | ||
| 5.5 | 10 | 3.6 or less |